Emerson Process Management Website Home Emerson Corporate Business Emerson Corporate Website Search Emerson Corporate  Website Emerson Corporate Businesses Emerson Corporate Investor Relations
Search Emerson Process Management WebsiteEmerson Process Management PlantWebEmerson Process Management Industry CentersEmerson Process Management News & EventsEmerson Process Management ContactsEmerson Process Management Global Presence



Power Industry Solutions
Water/WasteWater Industry Solutions










 



 

Building Ovation® Graphics (OV210-UNX)



  Duration
Five Days

Prerequisites
Students must be understand Ovation® point record fields and Ovation control algorithm structures. It is recommended that students attend OV100-UNX prior to attending this course. If the student will be heavily involved in creating control interfaces OV200-UNX-1.8.X or OV200-UNX-1.9.X is also recommended.

Description
This course will teach the user to build Ovation® system graphic diagrams. Students will learn how to use the Ovation Graphics Builder in various applications. Course topics include the layout and implementation of static and dynamic objects, linking to control, and creating perspective-type diagrams. Methods for standardizing information entities and control interfaces, and troubleshooting problems within graphics code are also covered. This course is intended for anyone who will build process diagram displays for the Ovation system.

Course Objectives
Upon successful completion of this course, using the reference material provided, the student will be able to :

  1. Describe the different coding areas within the graphic source code
  2. Build graphics to display live plant data
  3. Use various drawing techniques to create 3D graphics
  4. Interface graphics to the control system by using poke fields
  5. Design and implement macros to be used within graphics
  6. Use conditional statements to create dynamic indications in graphics
  7. Employ various techniques to make graphics code execute more efficiently
  8. Use various application programs within a graphic to perform specific actions
  9. Assess and correct problems in graphics with available tools

Course Components

Module 1

  • Understand the graphics environment
  • Access the Graphics Builder
  • Understand the building environment
  • Build a simple menu graphic
  • Build non-point-related display items
  • Apply 3-D drawing techniques

Module 2

  • Display non-graphic process point info
  • Display graphic process point
  • Configure basic conditional expressions
  • Apply other poke types

Module 3

  • Build shapes
  • Use point groups
  • Apply window diagrams
  • Use the integrated source editor
  • Use generic text editor
  • Apply non-glyph commands

Module 4

  • Understand application programs
  • Interface to control
  • Build macros
  • Use macros

Module 5

  • Customize PD windows
  • Apply basic $P pointer techniques
  • Optimize diagram execution
  • Solve problems

Return to Ovation Training Index Page

 
   
OV001-UNX Ovation® Project Planning
OV001-WIN Ovation® Project Planning
OV010-UNX Ovation® Operator
OV010-WIN Ovation® Operator
OV100-UNX Starting with Data Acquisition
OV100-WIN Starting with Data Acquisition
OV115-WIN Solaris to Windows®
OV120-UNX Upgrade to Ovation®
OV120-WIN Upgrade to Ovation®
OV200-UNX-1.8X Building & Maintaining Ovation® Control (AutoCAD)
OV200-UNX-1.9X Building & Maintaining Ovation® Control (AutoCAD-free)
OV200-WIN-3.0X Building & Maintaining Ovation® Control
OV200-WIN-3.1X Building & Maintaining Ovation® Control
OV210-UNX Building Ovation® Graphics
OV210-WIN Building Ovation® Graphics
OV215-WIN Ovation® Software Project
OV216-WIN Ovation® Hardware Project
OV217-UNX-1.8.X Hardware/ Software Project
OV220-UNX Ovation® System Installation
OV220-WIN Ovation® System Installation
OV230-UNX Ovation® System Administration
OV230-WIN Ovation® System Administration
OV240-UNX Ovation® Historical Data Collection & Reports
OV240-WIN Ovation® Enterprise Historian (eDB)
OV245-WIN Ovation® Process Historian
OV246-WIN Ovation® Report Building
OV248-WIN EDS™
OV250-UNX Configuring the Ovation® Serial Link Controller I/O Module
OV250-WIN Configuring the Ovation® Serial Link Controller I/O Module
OV260-UNX Configuring the Ovation® Data Link Server
OV265 Ovation® Expert Transition
OV270-UNX Ovation® with HART and Smart Devices
OV270-WIN Ovation® with HART and Smart Devices
OV275-WIN AMS™ Suite: Intelligent Device Manager
OV280-WIN Ovation® SCADA System
OV295-UNX/
OV295-WIN
Ovation Third-Party I/O Interfaces
OV300-UNX Ovation® Troubleshooting
OV300-WIN Ovation® Troubleshooting
OV310-UNX Advanced Ovation® Graphics
OV310-WIN Advanced Ovation® Graphics
OV320-UNX Ovation® Network Administration
OV320-WIN Ovation® Network Administration
OV330-UNX Ovation® Advanced Control
OV330-WIN Ovation® Advanced Control
OV340-WIN Ovation® Applications with Fieldbus
OV360-WIN Ovation® Security for 2.4 and Higher Level Systems
OV370-WIN Ovation® Steam Turbine Control
OV380-WIN Ovation® Boiler Control
OV400-UNX Ovation® Certification
OV400-WIN Ovation® Certification
SP-GPA SmartProcess® Global Performance Advisor

 

 
   

Send comments to:
powerwater@emersonprocess.com


© Emerson, 1996-
Legal and Privacy Statements