Emerson Process Management Website Home Emerson Corporate Business Emerson Corporate Website Search Emerson Corporate  Website Emerson Corporate Businesses Emerson Corporate Investor Relations
Search Emerson Process Management WebsiteEmerson Process Management PlantWebEmerson Process Management Industry CentersEmerson Process Management News & EventsEmerson Process Management ContactsEmerson Process Management Global Presence



Power Industry Solutions
Water/WasteWater Industry Solutions










 



 

Ovation® Network Administration (OV320-WIN)



  Duration
Five Days

Scheduled Dates
Promo

  • February 4-8, 2008
  • August 4-8, 2008
  • October 20-24, 2008
  • December 15-19, 2008

Prerequisites
Prior completion of the OV230-WIN course is recommended, but not required.

Description
This introductory networking course will provide students with an understanding of general networking concepts, as well as Ovation®-specific network configurations for Fast Ethernet systems. Students will learn the basic networking skills required for general network administration and troubleshooting. Students will also be provided with hands-on knowledge of switch and router configuration for use in Ovation systems. This course is intended for Ovation network administrators, Ovation system administrators, and those wishing to complete the Ovation Certification Program.

Course Objectives
Upon successful completion of this course, using the reference material provided, the student will be able to:

  1. Explore basic networking concepts including the OSI reference model, MAC addressing, TCP/IP, IP addressing, multicast addressing and local area networks
  2. Implement an Ovation-specific network addressing scheme and network topology
  3. Define and explore basic network commands
  4. Define network devices and media, and their relation to the OSI reference model
  5. Configure Cisco 2600 series routers, Cisco 3550 series switches, and Cisco 2950 series switches for use in an Ovation network (where applicable)
  6. Configure and implement SNMP for Ovation
  7. Troubleshoot inter-networked systems with network tools and software
  8. Configure and apply third-party networking software

Course Components

Module 1

  • Understand and use the ipconfig command
  • Understand and use the ping command
  • Understand and use the arp command
  • Understand and use the netstat command
  • Understand and use the traceroute command
  • Understand and use the telnet command
  • Understand how to use Universal Naming Convention (UNC)

Module 2

  • Understand the principles defined by the OSI reference model
  • Relate the OSI reference model to logical and physical devices on a network
  • Understand the OSI reference models value in troubleshooting network problems

Module 3

  • Define media types used in networking
  • Build straight through and crossover Ethernet cables
  • Put into operation fiber optic media converters

Module 4

  • Define and understand media access control, its addressing scheme and its place in the OSI reference model
  • Understand the Ethernet protocol and its place in the OSI reference model
  • Define and understand the composition and function of the Ethernet frame.
  • Define the function of a switch

Module 5

  • Define and understand IP addressing, including subnet masks and subnets
  • Define and implement Ovation specific IP addressing and topology schemes
  • Define the function of layer 3 switches and routers

Module 6

  • Define and understand the TCP/IP Internet Protocol Suite
  • Define and understand the concept of ports
  • Define the basis of access control lists

Module 7

  • Understand and use Cisco IOS commands
  • Upgrade the Cisco IOS on a network device
  • Upload a network device configuration file
  • Construct an access control list

Module 8

  • Understand the function of and edit the host file
  • Understand the function the bootptab file
  • Understand the function of Simple Network Management Protocol (SNMP)
  • Create and implement an SNMP file

Module 9

  • Understand hardware troubleshooting tools and their effect on the Ovation network
  • Understand software troubleshooting tools and their effect on the Ovation network
  • Discuss the loading of validated third-party networking software

Return to Ovation Training Index Page

 
   
OV001-UNX Ovation® Project Planning
OV001-WIN Ovation® Project Planning
OV010-UNX Ovation® Operator
OV010-WIN Ovation® Operator
OV100-UNX Starting with Data Acquisition
OV100-WIN Starting with Data Acquisition
OV120-UNX Upgrade to Ovation®
OV120-WIN Upgrade to Ovation®
OV200-UNX-1.8X Building & Maintaining Ovation® Control (AutoCAD)
OV200-UNX-1.9X Building & Maintaining Ovation® Control (AutoCAD-free)
OV200-WIN-3.0X Building & Maintaining Ovation® Control
OV200-WIN-3.1X Building & Maintaining Ovation® Control
OV210-UNX Building Ovation® Graphics
OV210-WIN Building Ovation® Graphics
OV215-WIN Ovation® Software Project
OV216-WIN Ovation® Hardware Project
OV220-UNX Ovation® System Installation
OV220-WIN Ovation® System Installation
OV230-UNX Ovation® System Administration
OV230-WIN Ovation® System Administration
OV240-UNX Ovation® Historical Data Collection and Reports
OV240-WIN Ovation® Enterprise Historian (eDB)
OV245-WIN Ovation® Process Historian
OV248-WIN EDS™
OV250-UNX Configuring the Ovation® Serial Link Controller I/O Module
OV250-WIN Configuring the Ovation® Serial Link Controller I/O Module
OV260-UNX Configuring the Ovation® Data Link Server
OV270-UNX Ovation® with HART and Smart Devices
OV270-WIN Ovation® with HART and Smart Devices
OV275-WIN AMS™ Suite: Intelligent Device Manager
OV280-WIN Ovation® SCADA System
OV290-UNX Third-Party Interfaces Between Ovation and Both an Allen-Bradley PLC and a Modbus Device (OV290-UNX)
OV290-WIN Third-Party Interfaces Between Ovation and Both an Allen-Bradley PLC and a Modbus Device (OV290-WIN)
OV300-UNX Ovation® Troubleshooting
OV300-WIN Ovation® Troubleshooting
OV310-UNX Advanced Ovation® Graphics
OV310-WIN Advanced Ovation® Graphics
OV320-UNX Ovation® Network Administration
OV320-WIN Ovation® Network Administration
OV330-UNX Ovation® Advanced Control
OV330-WIN Ovation® Advanced Control
OV340-WIN Ovation® Applications with Fieldbus
OV360-WIN Ovation® Security for 2.4 and Higher Level Systems
OV370-WIN Ovation® Steam Turbine Control
OV380-WIN Ovation® Boiler Control
OV400-UNX Ovation® Certification
OV400-WIN Ovation® Certification
SP-GPA SmartProcess® Global Performance Advisor

 

 
   

Send comments to:
powerwater@emersonprocess.com


Last Updated 2/8/08


© Emerson, 1996-2008
Legal and Privacy Statements