Emerson Process Management Website Home Emerson Corporate Business Emerson Corporate Website Search Emerson Corporate  Website Emerson Corporate Businesses Emerson Corporate Investor Relations
Search Emerson Process Management WebsiteEmerson Process Management PlantWebEmerson Process Management Industry CentersEmerson Process Management News & EventsEmerson Process Management ContactsEmerson Process Management Global Presence



Power Industry Solutions
Water/WasteWater Industry Solutions










 



 

Ovation® Certification
OV400-WIN



  Duration
Five Days

Prerequisites
Students must have a strong background and understanding of the Ovation® system architecture. Before enrolling in the Ovation Certification course, students are required to have completed the following Ovation Windows courses:

It is also recommended, but not required, that students complete the OV250-WIN course, if applicable to their particular Ovation system.

Description
The Ovation certification course is a rigorous five-day examination designed to measure a student's proficiency in all htmects of Ovation system administration, configuration and operation. The culmination of an extensive Ovation training regimen (see prerequisites above), this course is designed to ascertain if an individual has acquired the skills and knowledge necessary to successfully load, configure, operate, and administer an Ovation control system. Earning Ovation certification acknowledges the student's expertise in working with Ovation products and technologies and his/her ability to apply acquired knowledge in real-world situations. As part of the examination, students will be required to work independently to build and configure an Ovation system. Tasks will include system loading, configuration, database and control building, graphic design and linkage, report generation and system backup. Students will also be required to troubleshoot problems as they occur. Although this course will be led by an Ovation instructor, students will be required to complete the examination/exercises without significant input from the Emerson training staff.

Students will receive certification upon satisfactory completion of this course. In order to maintain their skills and keep current with software updates, successful students will be entitled to free admittance to future training courses on topics related to Ovation software updates/upgrades. These "software update" courses will be scheduled as new versions of the software are released. Ovation certification will be valid for three years.

Course Objectives
Upon successful completion of this course, the student will receive Ovation certification. This credential affirms that the student is an experienced technical leader with the ability to successfully engineer, administer and maintain an Ovation control system for his/her organization. Upon certification, the student will have an integral knowledge of all htmects of an Ovation system. Each student will be able to design, configure and implement an Ovation system from its component level, demonstrating proficiency in all areas including:

  1. Loading and licensing the Ovation software server workstation
  2. Loading and configuring the Ovation controller
  3. Loading and licensing the historian
  4. Building, saving and implementing the Oracle database
  5. Constructing control sheets using both Boolean and analog logic
  6. Designing graphics with control linkage
  7. Importing the database into the historian or enterprise historian
  8. Building and generating historical reports
  9. Performing procedures to backup the system

Course Components

Module 1

  • Assemble workstation and all peripheral devices
  • Connect the controller and all cabling to a switch
  • Load the workstation with latest version of Windows and Ovation
  • Configure Ovation workstation for proper functionality
  • Download the workstation and controller and get everything on the highway
  • Install the required third-party software (i.e., Autocad  and Applix)
  • License all required software
Module 2

  • Build database with required points of the proper types using the Developer Studio
  • Configure the proper security for the database
  • Load the controller and verify that points are on the highway
  • Create PIC file for collection of necessary points by the Historian
  • Verify the collection of historical points
Module 3
  • Choose the type of control scheme desired for certification (i.e., temp, level, flow, etc.)
  • Build the control sheets necessary for this control application using the Control Builder
  • Load the controller with new sheets and verify correct functionality
  • Demonstrate that control sheets are interconnected through page connector

Module 4

  • Design graphic interface to selected control scheme
  • Build the graphic with proper functionality using the Graphics Builder
  • Download the graphic and test correct operation
  • Demonstrate the functionality of all aspects of the control scheme (i.e., auto/man, tracking, etc.)

Module 5

  • Verify collection of all control points by the Historian through historical trends
  • Design a report for displaying both live and historical data
  • Build a report using the appropriate software and download the report
  • Generate report and verify printout for proper layout and data
Module 6

  • Perform a partial backup of the database using ptdbexp
  • Perform a complete backup of the database using exp
  • Create a backup of the file systems to a tape or disk

Return to Ovation Training Index Page


 
   
OV001-UNX Ovation® Project Planning
OV001-WIN Ovation® Project Planning
OV010-UNX Ovation® Operator
OV010-WIN Ovation® Operator
OV100-UNX Starting with Data Acquisition
OV100-WIN Starting with Data Acquisition
OV115-WIN Solaris to Windows®
OV120-UNX Upgrade to Ovation®
OV120-WIN Upgrade to Ovation®
OV200-UNX-1.8X Building & Maintaining Ovation® Control (AutoCAD)
OV200-UNX-1.9X Building & Maintaining Ovation® Control (AutoCAD-free)
OV200-WIN-3.0X Building & Maintaining Ovation® Control
OV200-WIN-3.1X Building & Maintaining Ovation® Control
OV210-UNX Building Ovation® Graphics
OV210-WIN Building Ovation® Graphics
OV215-WIN Ovation® Software Project
OV216-WIN Ovation® Hardware Project
OV217-UNX-1.8.X Hardware/ Software Project
OV220-UNX Ovation® System Installation
OV220-WIN Ovation® System Installation
OV230-UNX Ovation® System Administration
OV230-WIN Ovation® System Administration
OV240-UNX Ovation® Historical Data Collection & Reports
OV240-WIN Ovation® Enterprise Historian (eDB)
OV245-WIN Ovation® Process Historian
OV246-WIN Ovation® Report Building
OV248-WIN EDS™
OV250-UNX Configuring the Ovation® Serial Link Controller I/O Module
OV250-WIN Configuring the Ovation® Serial Link Controller I/O Module
OV260-UNX Configuring the Ovation® Data Link Server
OV265 Ovation® Expert Transition
OV270-UNX Ovation® with HART and Smart Devices
OV270-WIN Ovation® with HART and Smart Devices
OV275-WIN AMS™ Suite: Intelligent Device Manager
OV280-WIN Ovation® SCADA System
OV295-UNX/
OV295-WIN
Ovation Third-Party I/O Interfaces
OV300-UNX Ovation® Troubleshooting
OV300-WIN Ovation® Troubleshooting
OV310-UNX Advanced Ovation® Graphics
OV310-WIN Advanced Ovation® Graphics
OV320-UNX Ovation® Network Administration
OV320-WIN Ovation® Network Administration
OV330-UNX Ovation® Advanced Control
OV330-WIN Ovation® Advanced Control
OV340-WIN Ovation® Applications with Fieldbus
OV360-WIN Ovation® Security for 2.4 and Higher Level Systems
OV370-WIN Ovation® Steam Turbine Control
OV380-WIN Ovation® Boiler Control
OV400-UNX Ovation® Certification
OV400-WIN Ovation® Certification
SP-GPA SmartProcess® Global Performance Advisor

 

 
   

Send comments to:
powerwater@emersonprocess.com


© Emerson, 1996-
Legal and Privacy Statements